HOME marketing@nivelco.com + 36 -1 - 889-0100


 PRESSURE >>> PRESSURE TRANSMITTER

 Technical data
Min. Medium temperatureInformationInformationHelp info for this ....
-40 °C -25 °C
  
Max. Medium temperatureInformationInformationHelp info for this ....
+125 °C +140 °C
+125 °C +300 °C
Process connectionInformationInformationHelp info for this ....
1" 1 1/2"
1" 1/2"
1/4" 11"
2" 3"
3/4" Flanges
TriClamp Sanitary
  
Measurement TechniqueInformationInformationHelp info for this ....
Absolute Relative
Electrical connectionInformationInformationHelp info for this ....
DIN Connector Integrated cable
  
DisplayInformationInformationHelp info for this ....
Indicator with DIN connector
AccuracyInformationInformationHelp info for this ....
0,1 % 0,2 %
0,25 % 0,5 %
1 %
  
OutputInformationInformationHelp info for this ....
0…10 V 0 - 10 V
4...20 mA 4…20 mA
HART®
Properties of the measured mediumInformationInformationHelp info for this ....
Agressive Build-up
Dynamic pressure change High pressure resistance
Static pressure change Contanimated
Clean Sediment
  

 
 PRESSURE
  Pressure transmitter
        NIPRESS D-200 – ceramic internal diaphragm  
        NIPRESS D-300 – stainless steel internal diaphragm  
        NIPRESS D-400 – stainless steel flush diaphragm
        NIPRESS D-500 – ceramic flush diaphragm
        NIPRESS D-600 – ceramic flush diaphragm
        NIPRESS D-700 – ceramic flush diaphragm
        NIPRESS D-800 – stainless steel flush diaphragm
        NIPRESS D-900 – ceramic internal diaphragm
        NIPRESS D-A00 – flush or internal diaphragm
        NIPRESS D-B00 – ceramic flush diaphragm
        NIPRESS D-C00 – stainless steel internal diaphragm

 NIPRESS D-200
  – ceramic internal diaphragm
Sensor: ceramic
Pressure gauge: 0…400 bar
Accuracy: 0.5%
Output: 4…20 mA, 0…10 V
Process connection: 1", 1" BSP, 1" NPT
Protection: IP65, IP67
 
 NIPRESS D-300
  – stainless steel internal diaphragm
Sensor: stainless steel
Pressure gauge: 0…600 bar
Accuracy: 0.1 / 0.25 / 0.5%
Output: 4…20 mA, 0…10 V
Process connection: 1", 1" BSP, 1", 1" NPT
Protection: IP65, IP67, IP68
 
 NIPRESS D-400
  – stainless steel flush diaphragm
Sensor: stainless steel
Pressure gauge: 0…400 bar
Accuracy: 0.25 / 0.5%
Output: 4…20 mA, 0…10 V Process connection: 1", 3", 1" BSP; 3", 11", 2"; Triclamp; DN25, DN25, DN40/50 sanitary DN40/50 VARIVENT
Protection: IP65, IP67, IP68
 NIPRESS D-500
  – ceramic flush diaphragm
Sensor: ceramic
Pressure gauge: 0…600 bar
Accuracy: 0.5%
Output: 4…20 mA, 0…10 V
Process connection: 1", 1" BSP; 1", 1" NPT
Protection: IP65, IP67, IP68
 
 NIPRESS D-600
  – ceramic flush diaphragm
Sensor: ceramic
Pressure gauge: 0…60 bar
Accuracy: 0.5%
Output: 4…20 mA, 0…10 V
Process connection: 3" BSP
Protection: IP65, IP67, IP68
 
 NIPRESS D-700
  – ceramic flush diaphragm
Sensor: ceramic
Pressure gauge: 0…20 bar
Accuracy: 0.25 / 0.5 / 1%
Output: 4…20 mA, 0…10 V
Process connection: 11" BSP
Protection: IP65, IP67, IP68
 NIPRESS D-800
  – stainless steel flush diaphragm
Sensor: stainless steel
Pressure gauge: 0…40 bar
Accuracy: 0.1 / 0.25 / 0.5%
Output: 4…20 mA, 0…10 V
Process connection: 3" BSP
Protection: IP65, IP67, IP68
 
 NIPRESS D-900
  – ceramic internal diaphragm
Sensor: ceramic
Pressure gauge: 0 – 20 bar
Accuracy: 0.25 / 0.5%
Output: 4 – 20 mA, 0 – 10V
Process connection: 1/2" BSP, 1/2" NPT
Protection: IP65, IP67, IP68
 
 NIPRESS D-A00
  – flush or internal diaphragm
Sensor: stainless steel
Pressure gauge: 0…600 bar
Accuracy: 0.1%
Output: 4…20 mA, HART®
Process connection: 1" BSP, 1" NPT, 1" BSP, 11" BSP; DN25/PN40, DN50/PN40, DN80/PN40, 2" RF, 3" RF
Protection: IP67
 NIPRESS D-B00
  – ceramic flush diaphragm
Sensor: ceramic
Pressure gauge: 0…20 bar
Accuracy: 0.1 / 0.2%
Output: 4…20 mA, HART®
Process connection: 1", 1", 11" BSP; 1" NPT; DN25/PN40, DN50/PN40, DN80/PN40, 2" RF, 3" RF
Protection: IP67
 
 NIPRESS D-C00
  – stainless steel internal diaphragm
Sensor: stainless steel
Pressure gauge: 0…2000 bar
Accuracy: 0.5%
Output: 4…20 mA, 0…10 V
Process connection: 11” BSP; M20 x1.5 internal thread
Protection: IP65, IP67