Type | |
D |
 |
 |
– |
 |
 |
1 |
– |
 |
|
|
|
Version | |
D |
 |
 |
– |
 |
 |
1 |
– |
 |
|
|
|
|
T |
|
|
|
|
|
|
|
|
Transmitter |
|
|
B |
|
|
|
|
|
|
|
|
Transmitter with local LCD display |
|
Process connection | |
D |
 |
 |
– |
 |
 |
1 |
– |
 |
|
|
|
|
|
K |
|
|
|
|
|
|
|
½" BSP (p > 2.5 bar) |
|
|
|
E |
|
|
|
|
|
|
|
1" BSP |
|
|
|
F |
|
|
|
|
|
|
|
1½" BSP |
|
|
|
L |
|
|
|
|
|
|
|
1" TriClamp (ISØ 2852, 0,25…16 bar)
|
|
|
|
M |
|
|
|
|
|
|
|
1½" TriClamp (ISØ 2852, p ≤ 16 bar) |
|
|
|
N |
|
|
|
|
|
|
|
2" TriClamp (ISØ 2852, p ≤ 16 bar) |
|
|
|
O |
|
|
|
|
|
|
|
DN25 Pipe coupling (DIN 11851, 0.25…40 bar) |
|
|
|
P |
|
|
|
|
|
|
|
DN40 Pipe coupling (DIN 11851, 0.25…40 bar) |
|
|
|
R |
|
|
|
|
|
|
|
DN50 Pipe coupling (DIN 11851, 0.25…25 bar) |
|
Housing | |
D |
 |
 |
– |
 |
 |
1 |
– |
 |
|
|
|
|
|
|
|
5 |
|
|
|
|
|
Painted aluminum |
|
|
|
|
|
6 |
|
|
|
|
|
Plastic, PBT, fiberglass-reinforced |
|
|
|
|
|
7 |
|
|
|
|
* |
Stainless steel |
|
* Ex version under approval |
Range (gauge) / Overpressure | |
D |
 |
 |
– |
 |
 |
1 |
– |
 |
|
|
|
|
|
|
|
|
1 |
|
|
|
|
0…0.16 bar / 0.5 bar (with min. 1" process connection) |
|
|
|
|
|
|
2 |
|
|
|
|
0…0.25 bar / 1 bar (with min. 1" process connection) |
|
|
|
|
|
|
3 |
|
|
|
|
0…0.4 bar / 1 bar (with min. 1" process connection) |
|
|
|
|
|
|
4 |
|
|
|
|
0…0.6 bar / 3 bar (with min. 1" process connection) |
|
|
|
|
|
|
5 |
|
|
|
|
0…1 bar / 3 bar (with min. 1" process connection) |
|
|
|
|
|
|
6 |
|
|
|
|
0…1.6 bar / 6 bar (with min. 1" process connection) |
|
|
|
|
|
|
7 |
|
|
|
|
0…2.5 bar / 6 bar |
|
|
|
|
|
|
8 |
|
|
|
|
0…4 bar / 20 bar |
|
|
|
|
|
|
9 |
|
|
|
|
0…6 bar / 20 bar |
|
|
|
|
|
|
A |
|
|
|
|
0…10 bar / 20 bar |
|
|
|
|
|
|
B |
|
|
|
|
0…16 bar / 60 bar |
|
|
|
|
|
|
C |
|
|
|
|
0…25 bar / 60 bar |
|
|
|
|
|
|
D |
|
|
|
|
0…40 bar / 100 bar |
|
|
|
|
|
|
E |
|
|
|
|
0…60 bar / 120 bar |
|
|
|
|
|
|
F |
|
|
|
|
0…100 bar / 250 bar
|
|
|
|
|
|
|
G |
|
|
|
|
0…160 bar / 500 bar
|
|
|
|
|
|
|
H |
|
|
|
|
0…250 bar / 500 bar
|
|
|
|
|
|
|
J |
|
|
|
|
0…400 bar / 600 bar |
|
Output / Certificates | |
D |
 |
 |
– |
 |
 |
1 |
– |
 |
|
|
|
|
|
|
|
|
|
|
|
2 |
|
4…20 mA |
|
|
|
|
|
|
|
|
|
4 |
|
4…20 mA + HART®
|
|
|
|
|
|
|
|
|
|
6 |
|
4…20 mA / Ex ia G |
|
|
|
|
|
|
|
|
|
8 |
|
4…20 mA + HART® / Ex ia G |
|