HOME marketing@nivelco.com + 36 -1 - 889-0100


 

 Offer – Print – More devices 
 NIPRESS - PRESSURE TRANSMITTER
D ? ? 5 ? ? ?

 Type
D 5
 Measuring method
D 5
R Gauge
E Absolute
 Process connection
D 5
A ¼" BSP (inner diaphragm version only)
C ½" BSP (inner or optional flush diaphragm version)
G ¼" NPT (inner diaphragm version only)
H ½" NPT (inner diaphragm version only)
J M20x1.5 (inner diaphragm version only)
 Range / Overpressure* / Membrane design
D 5
0 –1…0 bar / 4 bar / inner (only with 1% accuracy)
3 0…0.4 bar / 1 bar / inner or optional flush diaphragm
4 0…0.6 bar / 2 bar / inner or optional flush diaphragm
5 0…1 bar / 2 bar / inner or optional flush diaphragm
6 0…1.6 bar / 4 bar / inner or optional flush diaphragm
7 0…2.5 bar / 4 bar / inner or optional flush diaphragm
8 0…4 bar / 10 bar / inner or optional flush diaphragm
9 0…6 bar / 10 bar / inner or optional flush diaphragm
A 0…10 bar / 20 bar / inner or optional flush diaphragm
B 0…16 bar / 40 bar / inner or optional flush diaphragm
C 0…25 bar / 40 bar / inner or optional flush diaphragm
D 0…40 bar / 100 bar / inner
E 0…60 bar / 100 bar / inner
F 0…100 bar / 200 bar / inner
G 0…160 bar / 400 bar / inner
H 0…250 bar / 400 bar / inner
J 0…400 bar / 600 bar / inner
K 0…600 bar / 800 bar / inner
 * Custom measuring range, based on prior negotiations.
 Accuracy
D 5
2 0.5%
3 1% (only with PTFE coated version or underpressure ranges)
 Output / Certificates
D 5
2 4…20 mA
3 0…10 V
6 ** 4…20 mA / Ex ia G
C ** 4…20 mA, SIL 2
D ** 4…20 mA, SIL 2 / Ex ia G
 ** Ex or SIL versions are available on request.

D ? ? 5 ? ? ?
 Offer – Print – More devices 

 



D_C-5_2-_