Type | |
H |
 |
 |
– |
 |
 |
 |
– |
 |
|
|
|
Version / Temperature | |
H |
 |
 |
– |
 |
 |
 |
– |
 |
|
|
|
|
T |
|
|
|
|
|
|
|
|
Transmitter / Flange temperature max. +90 °C |
|
|
H |
|
|
|
|
|
|
|
|
High-temperature transmitter / Flange temp. max. +200 °C (M type only up to +150 °C) |
|
|
B |
|
|
|
|
|
|
|
|
Transmitter with local LCD display / Flange temperature max. +90 °C |
|
|
P |
|
|
|
|
|
|
|
|
High-temperature transmitter with local LCD display / Flange temp. max. +200 °C (M type only up to +150 °C) |
|
Probe / Process connection | |
H |
 |
 |
– |
 |
 |
 |
– |
 |
|
|
|
|
|
K |
|
|
|
|
|
|
|
Mono cable, Ø4 mm, 1.4401 / 1" BSP / max. 30 m |
|
|
|
L |
|
|
|
|
|
|
|
Mono cable, Ø4 mm, 1.4401 / 1" NPT / max. 30 m |
|
|
|
V |
|
|
|
|
|
|
|
Mono cable, Ø4 mm, 1.4401 / 1½" BSP / max. 30 m |
|
|
|
W |
|
|
|
|
|
|
|
Mono cable, Ø4 mm, 1.4401 / 1½" NPT / max. 30 m |
|
|
|
1 |
|
|
|
|
|
|
|
Mono cable, Ø4 mm, 1.4401 / 1½" TriClamp / max. 30 m |
|
|
|
2 |
|
|
|
|
|
|
|
Mono cable, Ø4 mm, 1.4401 / 2" TriClamp / max. 30 m |
|
|
|
N |
|
|
|
|
|
|
|
Mono cable, Ø8 mm, 1.4401 / 1½" BSP / max. 30 m |
|
|
|
J |
|
|
|
|
|
|
|
Mono cable, Ø8 mm, 1.4401 / 1½" NPT / max. 30 m |
|
|
|
T |
|
|
|
|
|
|
|
Twin cable, 2x Ø4 mm, 1.4401 / 1½" BSP / max. 30 m |
|
|
|
U |
|
|
|
|
|
|
|
Twin cable, 2x Ø4 mm, 1.4401 / 1½" NPT / max. 30 m |
|
|
|
F |
|
|
|
|
|
|
* |
Mono cable, Ø4 mm, + FEP-coated / 1" BSP / max. 30 m |
|
|
|
G |
|
|
|
|
|
|
* |
Mono cable, Ø4 mm, + FEP-coated / 1" NPT / max. 30 m |
|
|
|
X |
|
|
|
|
|
|
* |
Mono cable, Ø4 mm, + FEP-coated / TriClamp 1½" / max. 30 m |
|
|
|
Y |
|
|
|
|
|
|
* |
Mono cable, Ø4 mm, + FEP-coated / Sanitary DN40 / max. 30 m |
|
|
|
M |
|
|
|
|
|
|
|
Mono cable, Ø4 mm, + PFA/FEP fully coated / DN50, PN25, 1.4571 + PFA/FEP lining |
|
* Only the cable probe is coated |
Housing | |
H |
 |
 |
– |
 |
 |
 |
– |
 |
|
|
|
|
|
|
|
7 |
|
|
|
|
|
Painted aluminum |
|
|
|
|
|
8 |
|
|
|
|
|
Plastic, PBT, fiberglass-reinforced (Ex version not available) |
|
|
|
|
|
9 |
|
|
|
|
|
Stainless steel |
|
Probe length / Material | |
H |
 |
 |
– |
 |
 |
 |
– |
 |
|
|
|
|
|
|
|
|
|
|
|
n |
n |
|
|
|
1.0…30.0 m (sold by the meter), for mono cable, Ø4 mm / 1.4401 |
|
|
|
|
|
|
n |
n |
|
|
|
1.0…30.0 m (sold by the meter), for mono cable, Ø8 mm / 1.4401 |
|
|
|
|
|
|
n |
n |
|
|
|
1.0…30.0 m (sold by the meter), for twin cable / 1.4401 |
|
|
|
|
|
|
n |
n |
|
|
|
1.0…30.0 m (sold by the meter), for mono cable, Ø4 mm / 1.4401 + FEP |
|
nn = 01…30 : 1.0…30.0 m |
Output / Certificates | |
H |
 |
 |
– |
 |
 |
 |
– |
 |
|
|
|
|
|
|
|
|
|
|
|
4 |
|
4…20 mA + HART® |
|
|
|
|
|
|
|
|
|
5 |
|
4…20 mA + HART® / Ex ta/tb D (only for uncoated probe versions) |
|
|
|
|
|
|
|
|
|
6 |
|
4…20 mA + HART® / Ex ia D (only for uncoated probe versions) |
|
|
|
|
|
|
|
|
|
8 |
|
4…20 mA + HART® / Ex ia G (plastic-coated probes Ex ia IIB only) |
|
|
|
|
|
|
|
|
|
9 |
|
4…20 mA + HART® / Ex ta D (only for uncoated probe versions) |
|
|
|
|
|
|
|
|
|
H |
|
4…20 mA + HART® + Relay |
|