Type
| |
D |
 |
 |
– |
4 |
 |
 |
– |
 |
|
|
|
Measuring method
| |
D |
 |
 |
– |
4 |
 |
 |
– |
 |
|
|
|
|
R |
|
|
|
|
|
|
|
|
Gauge up to +125 °C
|
|
|
E |
|
|
|
|
|
|
|
|
Absolute up to +70 °C (p ≥ 0.6 bar)
|
|
|
H |
|
|
|
|
|
|
|
|
Gauge up to +150 °C (p ≤ 160 bar)
|
|
|
J |
|
|
|
|
|
|
|
|
Gauge up to +300 °C (p ≤ 160 bar, p ≤ 70 bar max. +200 °C permanent)
|
|
Process connection
| |
D |
 |
 |
– |
4 |
 |
 |
– |
 |
|
|
|
|
|
B |
|
|
|
|
|
|
|
½" BSP (p > 1.5 bar)
|
|
|
|
C |
|
|
|
|
|
|
|
½" BSP (sensor: 1.4404) max. +125 °C, -1…40 bar; without media separator
|
|
|
|
J |
|
|
|
|
|
|
|
M20x1.5 (p > 2.5 bar) |
|
|
|
D |
|
|
|
|
|
|
|
¾" BSP (p > 0.6 bar) |
|
|
|
E |
|
|
|
|
|
|
|
1" BSP (p > 0.25 bar)
|
|
|
|
S |
|
|
|
|
|
|
|
1" NPT (0.25…40 bar) |
|
|
|
F |
|
|
|
|
|
|
|
1½" BSP
|
|
|
|
T |
|
|
|
|
|
|
|
¾" TriClamp (4…8 bar) |
|
|
|
L |
|
|
|
|
|
|
|
1" TriClamp (0.25…16 bar)
|
|
|
|
M |
|
|
|
|
|
|
|
1½" TriClamp (p ≤ 16 bar)
|
|
|
|
N |
|
|
|
|
|
|
|
2" TriClamp (p ≤ 16 bar)
|
|
|
|
O |
|
|
|
|
|
|
|
DN25 Pipe coupling (DIN 11851; 0.25…40 bar)
|
|
|
|
P |
|
|
|
|
|
|
|
DN40 Pipe coupling (DIN 11851; 0.25…40 bar)
|
|
|
|
R |
|
|
|
|
|
|
|
DN50 Pipe coupling (DIN 11851; 0.25…25 bar)
|
|
|
|
I |
|
|
|
|
|
|
|
DN25 / PN40 1.4404 flange (p ≤ 40 bar) |
|
|
|
Q |
|
|
|
|
|
|
|
DN50 / PN40 1.4404 flange (p ≤ 40 bar) |
|
|
|
U |
|
|
|
|
|
|
|
DN80 / PN16 1.4404 flange (p ≤ 16 bar) |
|
|
|
K |
|
|
|
|
|
|
|
DN100 / PN16 1.4404 flange (p ≤ 16 bar) |
|
|
|
V |
|
|
|
|
|
|
|
VARIVENT® DN40 / 50 (p ≤ 10 bar) |
|
Range / Overpressure*
| |
D |
 |
 |
– |
4 |
 |
 |
– |
 |
|
|
|
|
|
|
|
|
0 |
|
|
|
|
-1…0 bar / 5 bar (max. +70 °C)
|
|
|
|
|
|
|
1 |
|
|
|
|
0…0.1 bar / 0.5 bar
|
|
|
|
|
|
|
R |
|
|
|
|
0…0.16 bar / 1 bar |
|
|
|
|
|
|
2 |
|
|
|
|
0…0.25 bar / 1 bar
|
|
|
|
|
|
|
3 |
|
|
|
|
0…0.4 bar / 2 bar
|
|
|
|
|
|
|
4 |
|
|
|
|
0…0.6 bar / 5 bar
|
|
|
|
|
|
|
5 |
|
|
|
|
0…1 bar / 5 bar
|
|
|
|
|
|
|
6 |
|
|
|
|
0…1.6 bar / 10 bar
|
|
|
|
|
|
|
7 |
|
|
|
|
0…2.5 bar / 10 bar
|
|
|
|
|
|
|
8 |
|
|
|
|
0…4 bar / 20 bar
|
|
|
|
|
|
|
9 |
|
|
|
|
0…6 bar / 40 bar
|
|
|
|
|
|
|
A |
|
|
|
|
0…10 bar / 40 bar |
|
|
|
|
|
|
B |
|
|
|
|
0…16 bar / 80 bar
|
|
|
|
|
|
|
C |
|
|
|
|
0…25 bar / 80 bar
|
|
|
|
|
|
|
D |
|
|
|
|
0…40 bar / 105 bar
|
|
|
|
|
|
|
E |
|
|
|
|
0…60 bar / 100 bar
|
|
|
|
|
|
|
F |
|
|
|
|
0…100 bar / 200 bar
|
|
|
|
|
|
|
G |
|
|
|
|
0…160 bar / 400 bar
|
|
|
|
|
|
|
H |
|
|
|
|
0…250 bar / 400 bar
|
|
|
|
|
|
|
J |
|
|
|
|
0…400 bar / 600 bar
|
|
* Custom measuring range, based on prior negotiations. |
Accuracy
| |
D |
 |
 |
– |
4 |
 |
 |
– |
 |
|
|
|
|
|
|
|
|
|
1 |
|
|
|
0.25% (0.4 bar ≤ p ≤ 40 bar)
|
|
|
|
|
|
|
|
2 |
|
|
|
0.5%
|
|
|
|
|
|
|
|
4 |
|
|
|
0.1% (only for DRC, DEC types) |
|
Output / Certificates
| |
D |
 |
 |
– |
4 |
 |
 |
– |
 |
|
|
|
|
|
|
|
|
|
|
|
2 |
|
4…20 mA
|
|
|
|
|
|
|
|
|
|
3 |
|
0…10 V
|
|
|
|
|
|
|
|
|
|
6 |
** |
4…20 mA / Ex ia G |
|
|
|
|
|
|
|
|
|
C |
** |
4…20 mA, SIL 2 |
|
|
|
|
|
|
|
|
|
D |
** |
4…20 mA, SIL 2 / Ex ia G |
|
** Ex or SIL versions are available on request. |